![]() |
![]()
|
| Main Site > Software / IT Channel > Statistics > Control Charts | Search: | for |
|
Recalculating Control Limits
B From tedious time consuming task to opportunity for improvement. When applying control charts it is common practice to establish the control limits based on the process capability study and then use fix limits on the chart during production. This method is also frequently applied in SPC software programs. The advantage of using fixed limits is that limits can be calculated over a time period where the production was running stable, then that period can be used as a benchmark for future production. However, in real life there are always changes in the process, which result in the fixed control limits becoming invalid. If the process improves, fixed limits remain too wide and control charts will not properly register signals for out of control (thereby accepting when false - beta error is induced). As a result, process improvement and opportunities to reduce sampling frequency are overlooked. If the process becomes worse due to machine wear, changes in material, etc., the control limits are too narrow. This results in the SPC system reporting control chart points out of control that should not be, if the control limits were naturally calculated (rejecting true - alpha error is increased). This will cause frustration and reflect poorly on SPC methodology in the plant, because our SPC tools are improperly signaling problems, thereby causing operators and staff to waste time addressing conditions, which are simply part of common process variation and therefore the responsibility of management. Control limits can be managed to prioritize the efforts of operators and help allocate limited resources on the shop floor. This is done by setting control limits at 3 sigma for critical characteristics and perhaps 4 or 5 sigma for less critical characteristics or characteristics with a high Ppk value. There are good reasons to set control limits at particular values, but they should be re-evaluated regularly depending on production volume, but at least once every 3 months to minimize both alpha and beta error in control chart analysis. The number of control charts in use at most companies causes this regular control limit re-evaluation to be a daunting task. However, it can be automated very easily and it can be automated in a way that it will even help to identify which control charts need their control limits recalculated. New Indices: Pl and Plk Pl = (Stored UCL - Stored LCL) / (Calculated UCL - Calculated LCL) Plk = the minimum of: If the fixed control limits are the same as the calculated limits the Pl and Plk indices are equal to 1. An index higher than 1 indicates that the process has improved and the limits are too wide. An index smaller than 1 indicates the process has become worse and the limits are too narrow. In the report which can be created from the database you should be able to set alarms if an index is outside a specific range. We recommend that the Pl and Plk index should never be less than 1. In that case, control limits can easily generate out of control signals, which may not be present (alpha error). The report also allows you to set upper Pl and Plk limits or alarms for groups of characteristics. For example, critical characteristics with a Ppk value not exceeding 1.67 the control limits should be at 3 sigma and the Pl and Plk indices should not exceed 1.2. For less critical characteristics or characteristics with a Ppk value which exceeds 3 the Pl and Plk indices may be higher than 1.2. By running the report for groups of characteristics the user can quickly identify if "frozen" control limits need to be adjusted. The Report
All necessary information to analyze whether control limits need to be adjusted can be found in the report. For this characteristic all alarms are present. By implementing such a report the tedious task of analyzing control charts for validity of the limits is eliminated and the resulting report can be used as a tool to keep the process of continuous improvement on track. About The Authors Mr. Schaeffers has worked for a large number of companies in Europe and Asia implementing SPC and Six Sigma and implementing company wide SPC systems. Some of the companies are ST Microelectronics, 3M, Viasystems, Philips, Océ Copiers, Masterfoods, Fuji Photo Film, FINA, Xerox and Schmalbach Lubeca. Mr. Schaeffers can be reached via email at info@spc-itk.com. Craig Stephen is Vice President of SCS, a 21 year old firm devoted to the development and support of statistical software for Quality Assurance. http://www.DataLyzer.com Reproduction Without Permission Is Strictly Prohibited Copyright Requests Publish an Article: Do you have a Six Sigma tip, learning or case study? Share it with the largest community of Six Sigma professionals, and be recognized by your peers. It's a great way to promote your expertise and/or build your resume. Read more about submitting an article. Download the iSixSigma Toolbar for 1-Click access. Search Your Way. Everyday. Without Delay.
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Home | Discussion Forum | Event Calendar | Job Shop | |
| Link To iSixSigma | Rate This Page | Report A Problem | Free Content For Your Site | Submit Article For Publishing | |
| Terms of Service. ©2000-2008 iSixSigma. All rights reserved. v3.0lb, 1.8-C-246 |
About iSixSigma · Contact Us · Privacy Policy · Site Map. |